Industry
New Benchmark in High-Voltage Variable Frequency Direct-Drive | Hope Slanvert Addresses Industry Challenge of High-Speed Frequent Braking in Air Separation Oxygen Production Process

The 6000Nm³/h blast‑furnace‑supporting Vacuum Pressure Swing Adsorption (VPSA) oxygen generation unit at Anyang Yongxing Special Steel of Shagang Group serves as a key supporting project for the green transformation of special‑steel manufacturing in northern Henan. It adopts a process with linked centrifugal vacuum pumps and blowers for oxygen production. The equipment is subject to extremely demanding operating conditions, requiring long‑term high‑frequency cyclic acceleration and deceleration.
The core on‑site equipment comprises two centrifugal vacuum pumps driven by 6kV/800kW/275Hz permanent‑magnet motors, plus one blower driven by a 6kV/1200kW/250Hz permanent‑magnet motor.


The process imposes stringent control requirements:
In the 0–50% speed range: No special restrictions on acceleration or deceleration.
In the 50%–100% high-speed range: The blower shall complete acceleration within 6 seconds and deceleration within 3 seconds; the vacuum pump shall complete acceleration within 8 seconds and deceleration within 3 seconds. Such cyclic operation shall be sustained without over‑voltage or over‑current faults to guarantee zero system downtime.
First Adoption of High-Voltage Variable Frequency Direct-Drive to Overcome the Industry Challenge of High-Speed Frequent Braking

To address the regenerative over-voltage pain point caused by frequent and rapid deceleration of large-inertia high-speed permanent magnet motors in the VPSA oxygen production process, the Hope Slanvert R&D team conducted an in-depth analysis of the process logic, broke through the conventional mindset of four-quadrant or dynamic braking, and adopted a high-voltage variable frequency direct-drive solution for the first time.
June 2025 · Low-voltage simulation joint commissioning: Based on a low-voltage high-frequency test platform, simulated cyclic acceleration/deceleration conditions to verify response speed and control accuracy, validating the core algorithm.
April 2026 · 6kV platform testing: Using the motor manufacturer's 6kV permanent magnet motor test platform, precisely identified over-voltage risks during rapid deceleration under no-load and light-load conditions, and optimized the control strategies.
June 2026 · On-site full-condition commissioning: Matched with actual loads, piping systems, and complete adsorption tower process conditions; completed final commissioning and put into operation. The equipment has been running continuously and stably with zero over-voltage or over-current faults.
Tangible Project Outcomes
I. Comprehensive energy savings of over 15%
The conventional geared transmission structure has been eliminated, removing gear meshing mechanical losses and fully leveraging the high-efficiency advantages of permanent magnet motors – perfectly aligning with the energy-saving retrofit needs of the steel industry.
II. Torque response time ≤5ms
Precisely matches the cyclic speed-change process requirements of VPSA oxygen production. During frequent acceleration/deceleration cycling in the 50%–100% high-speed range, zero over-voltage or over-current faults occur, ensuring a stable and continuous oxygen supply for blast furnace oxygen-enriched smelting.
III. Capital cost reduction of over 20%
Compared with braking-resistor solutions, the two-quadrant high-speed permanent magnet direct-drive solution cuts costs by 20%; versus four-quadrant variable frequency drive solutions, the reduction reaches 41%. The simplified structure and advanced control technology also significantly lower subsequent operation and maintenance costs.
IV. Mean Time Between Failures (MTBF) more than doubled
This project represents the first application of two-quadrant high-voltage permanent magnet direct-drive technology for the frequent rapid acceleration/deceleration conditions of VPSA oxygen production, fully validating the maturity and reliability of the permanent magnet direct-drive solution.

The successful implementation of the Shagang Yongxing Special Steel VPSA oxygen production project is yet another practical testament to Hope Slanvert's technological strength. Building on nearly three decades of variable frequency drive expertise, the company will continue to deepen its presence in high-precision, high-speed drive applications, delivering more energy-efficient, cost-effective, and reliable integrated variable frequency drive solutions to industrial customers, and supporting the green, intelligent transformation and upgrading of the steel industry.